BreachCISA Alerts··1 min

Rockwell Automation Flex 5000 Adapter

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation Flex 5000 Adapter are affected: Flex 5000 Adapter 6.011 (CVE-2026-12659) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Flex 5000 Adapter Double Free Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deploye

0
BreachCISA Alerts··1 min

Siemens SICAM 8

View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SICAM 8 are affected: CPCI85 Central Processing/Communication vers:intdot/<26.

0
BreachCISA Alerts··1 min

SALTO ProAccess Space

View CSAF Summary Successful exploitation of this vulnerability allows an authenticated attacker to escalate privileges and access spaces outside their assigned partition, within the same Salto ProAccess Space installation or system. Exploitation requires valid authenticated operator credentials and the partition feature to be enabled; installations without partitioning are not affected. The following versions of SALTO ProAccess Space are affected: ProAccess Space <6.13 (CVE-2026-11889) CVSS Ven

0
BreachCISA Alerts··1 min

Rockwell Automation FactoryTalk DataMosaix

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to inject malicious scripts on the server. The following versions of Rockwell Automation FactoryTalk DataMosaix are affected: DataMosaix Private Cloud <=8.02 (CVE-2026-9292) CVSS Vendor Equipment Vulnerabilities v3 6.1 Rockwell Automation Rockwell Automation FactoryTalk DataMosaix Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastruct

0
BreachCISA Alerts··1 min

NASA Core Flight System (cFS) Health & Safety (HS) Application

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS) Application NULL Pointer Dereference Background Critical Infrastructure Sectors: Transportation Systems Countr

0
BreachCISA Alerts··1 min

Rockwell Automation Arena

View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed

0
BreachCISA Alerts··1 min

AutomationDirect Productivity Suite

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389, CVE-2026-60140, CVE-2026-57896, CVE-2026-60073, CVE-2026-61378) CVSS Vendor Equipment Vulnerab

0
BreachCISA Alerts··1 min

Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT are affected: 1756-EN3 <=V12.001 (CVE-2026-9653) 1756-EN2 <=V12.001 (CVE-2026-9653) 1756-ENBT V6.006 (CVE-2026-9653) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT Improper Validation of Integrity Check Value Background

0
BreachCISA Alerts··1 min

Establishing a Coordinated Vulnerability Disclosure Program to Work With Security Researchers

Developed by CISA, the National Security Agency (NSA) and international partners, this joint guidance contains best practices for software manufacturers and online service providers to design and implement a coordinated vulnerability disclosure (CVD) program for working with external security researchers that includes a clear vulnerability disclosure policy (VDP) and process for triaging, remediating and assigning Common Vulnerabilities and Exposures (CVE) identifiers to reported vulnerabilities

0
BreachCISA Alerts··1 min

ABB T-MAC Plus

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves the reported vulnerabilities. An attacker who successfully exploited any of these vulnerabilities could potentially compromise the system in different ways. The following versions of ABB T-MAC Plus are affected: T-MAC Plus 4.0-24 (CVE-2025-14771, CVE-2025-14772, CVE-2025-14773, CVE-2025-14774) CVSS Vendor Equipment Vulnerabilities v3 9.9 ABB ABB T-

0
BreachCISA Alerts··1 min

Rockwell Automation 1715-AENTR EtherNet/IP Adapter

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. The following versions of Rockwell Automation 1715-AENTR EtherNet/IP Adapter are affected: 1715-AENTR EtherNet/IP Adapter <=3.003 (CVE-2026-10577) CVSS Vendor Equipment Vulnerabilities v3 10 Rockwell Automation Rockwell Automation 1715-AENTR EtherNet/

0
BreachCISA Alerts··1 min

ABB Ability Edgenius

View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete control

0
BreachCISA Alerts··1 min

ABB Advant Master Online Builder

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory, where an incorrect version of Online Builder (ONB) was included in the media. An update is available that resolves the vulnerability, see details in Recommended immediate actions. The following versions of ABB Advant Master Online Builder are affected: Control Builder A <=1.4/4 (CVE-2025-13162) 800xA for Advant Master <=6.0.3-1, <=6.1.1-1, 6.1.1-3, 6.2.0-1 (CVE-2025-13162, CVE-2025-13

0
BreachCISA Alerts··1 min

CISA Urges SharePoint Hardening After New Exploitations

CISA is aware of active exploitation of vulnerabilities CVE-2026-32201, CVE-2026-45659, and CVE-2026-56164, enabling cyber threat actors to gain unauthorized access to on-premises SharePoint Server instances. These vulnerabilities affect all supported on-premises SharePoint Server versions (Subscription Edition, 2019, and 2016) and involve establishing remote code execution (RCE) and post-exploitation activities, such as stealing Internet Information Services (IIS) machine keys and performing de

0
BreachCISA Alerts··1 min

Improve Router Hygiene to Protect Against Russian State-Sponsored Targeting

Russian Government-Sponsored Activity Targets Poorly Configured and Vulnerable Devices Across Critical Sectors Executive summary Russian Federal Security Service (FSB) Center 16 cyber actors continue to exploit poorly configured and vulnerable networking devices worldwide, opportunistically compromising multiple critical infrastructure sector networks. This joint Cybersecurity Advisory (CSA) builds on FBI’s Russian Government Cyber Actors Targeting Networking Devices, Critical Infrastructure Pub

0
BreachCISA Alerts··1 min

OpenPLC v3

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to write arbitrary files to the filesystem and escalate this into arbitrary native code execution through the normal OpenPLC program compilation process, potentially resulting in code execution as the OpenPLC runtime user. The following versions of OpenPLC v3 are affected: OpenPLC v3 CVSS Vendor Equipment Vulnerabilities v3 9.9 OpenPLC OpenPLC v3 External Control of File Name or Path Background

0
BreachCISA Alerts··1 min

Schneider Electric PowerChute Serial Shutdown

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to overwrite critical files, forge or inject malicious log data, gain unauthorized account access, trigger denial‑of‑service conditions, truncate or alter logging information, reset user credentials, or expose sensitive information. The following versions of Schneider Electric PowerChute Serial Shutdown are affected: PowerChute Serial Shutdown <=1.4 CVSS Vendor Equipment Vulnerabilities v3 6.1 SuSE, Schneide

0
BreachCISA Alerts··1 min

Schneider Electric Easergy MiCOM Px40 Series

View CSAF Summary Schneider Electric is aware of a vulnerability in its Easergy MiCOM Px40 Series products. The [Easergy MiCOM Px40](https://www.se.com/ww/en/product-subcategory/4725-easergy-micom-px40-series/?filter=business-6-medium-voltage-distribution-and-grid-automation) is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. Failure to apply the mitigations provided below may risk unauthorized exposure of basic device identification through the SNMP

0
BreachCISA Alerts··1 min

Hitachi Energy PROMOD V

View CSAF Summary Hitachi Energy is aware of insecure HTTP transmission vulnerability in PROMOD V product versions listed in this document. This vulnerability could allow attackers to intercept or manipulate sensitive data in transit, potentially leading to credential theft, session hijacking, or unauthorized access. The following versions of Hitachi Energy PROMOD V are affected: PROMOD V vers:PROMOD_V/ Running PROMOD V->Digipede Grid. Alternatively, refer to the same section in the online help

0
BreachCISA Alerts··1 min

Hydro-Québec Le Circuit Electrique charging station backend

View CSAF Summary Successful exploitation of these vulnerabilities could lead to privilege escalation, or result in a denial-of-service attack. The following versions of Hydro-Québec Le Circuit Electrique charging station backend are affected: Le Circuit Electrique charging station backend CVSS Vendor Equipment Vulnerabilities v3 9.8 Hydro-Québec Hydro-Québec Le Circuit Electrique charging station backend Improper Access Control, Improper Restriction of Excessive Authentication Attempts, Insuffi

0
BreachCISA Alerts··1 min

Siemens Mendix Studio Pro

View CSAF Summary Mendix Studio Pro versions before V11.12 are affected by a file parsing vulnerability that could be triggered when the application reads specially crafted malicious project during the build pipeline. This could allow an attacker to execute arbitrary code in the context of that user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products

0
BreachCISA Alerts··1 min

Digi International PortServer TS, Digi One SP IA

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and gain access to restricted resources, obtain credentials, and inject malicious scripts. The following versions of Digi International PortServer TS, Digi One SP IA are affected: PortServer TS Digi One SP Digi One SP IA Digi One IA CVSS Vendor Equipment Vulnerabilities v3 5.9 Digi International Digi International PortServer TS, Digi One SP IA Incorrect Authorization, Improper Neut

0
BreachCISA Alerts··1 min

Hitachi Energy e-mesh EMS

View CSAF Summary Hitachi Energy is aware of a buffer overflow vulnerability that affects e-mesh EMS product versions listed in this document. Successful exploitation of this vulnerability could lead to a buffer overflow condition, potentially resulting in application outages (denial of service) and possible arbitrary code execution. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy e-mesh EMS are affected

0
BreachCISA Alerts··1 min

Labcenter Proteus 9

View CSAF Summary Successful exploitation of these vulnerabilities could disclose information and allow a malicious user to execute arbitrary code on affected installations. The following versions of Labcenter Proteus 9 are affected: Proteus 9.1_SP4_Build_42914 CVSS Vendor Equipment Vulnerabilities v3 7.8 Labcenter Electronics Labcenter Proteus 9 Out-of-bounds Write, Stack-based Buffer Overflow, Use After Free Background Critical Infrastructure Sectors: Communications, Critical Manufacturing, De

0
BreachCISA Alerts··1 min

Siemens SINEC OS

View CSAF Summary SINEC OS before V4.0 contains multiple vulnerabilities. Siemens has released a new version for RUGGEDCOM RST2428P and recommends to update to the latest version. The following versions of Siemens SINEC OS are affected: RUGGEDCOM RST2428P (6GK6242-6PA00) vers:intdot/ cork. syzbot reported the splat below. [0] The repro does the following: 1. Load a sk_msg prog that calls bpf_msg_cork_bytes(msg, cork_bytes) 2. Attach the prog to a SOCKMAP 3. Add a socket to the SOCKMAP 4. Activat

0
BreachCISA Alerts··1 min

Gardyn IoT Hub

View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control IoT Hub managed devices. The following versions of Gardyn IoT Hub are affected: Home Firmware Studio Firmware Cloud API <2.12.2026 (CVE-2026-13768, CVE-2026-55726, CVE-2026-54477) CVSS Vendor Equipment Vulnerabilities v3 10 Gardyn Gardyn IoT Hub Use of Hard-coded Credentials, Exposure of Sensitive System Information to an Unauthorized Control Sphere, Improper Neutralization

0
BreachCISA Alerts··1 min

CubeSpace CW0057 Reaction Wheel

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to upload arbitrary malicious firmware to the device. The following versions of CubeSpace CW0057 Reaction Wheel are affected: CW0057 Reaction Wheel CVSS Vendor Equipment Vulnerabilities v3 6.1 CubeSpace CubeSpace CW0057 Reaction Wheel Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors: Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: So

0
BreachCISA Alerts··1 min

ST Engineering iDirect iQ-Series Terminals

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to device information or cause a denial-of-service condition. The following versions of ST Engineering iDirect iQ-Series Terminals are affected: Evolution iQ‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057) 3315‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057) 9‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057) CVSS Vendor Equipment Vulnerabilitie

0
BreachCISA Alerts··1 min

Schneider Electric EasyLogic T150 and Saitel DP RTU

View CSAF Summary Successful exploitation of these vulnerabilities can allow an attacker to cause unauthorized access and exposure of sensitive information when the unauthenticated attacker accesses credentials stored within firmware or system files. The following versions of Schneider Electric EasyLogic T150 and Saitel DP RTU are affected: EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller <=11.06.30 (CVE-2026-9650) EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & C

0
BreachCISA Alerts··1 min

OFFIS DCMTK Toolkit

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to write files, access unauthorized information, exhaust memory, or crash affected DCMTK client or server processes. The following versions of OFFIS DCMTK Toolkit are affected: DCMTK <=3.7.0 (CVE-2026-50003, CVE-2026-50254, CVE-2026-35505, CVE-2026-52868, CVE-2026-44628) CVSS Vendor Equipment Vulnerabilities v3 9.8 OFFIS OFFIS DCMTK Toolkit Improper Limitation of a Pathname to a Restricted Directory ('Path

0
BreachCISA Alerts··1 min

Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M

View CSAF Summary Successful exploitation of these vulnerabilities could allow a local attacker to tamper with or destroy information in the affected product, cause a denial-of-service condition in the affected product, or execute arbitrary code when a specially crafted archive file is decompressed by the 7-Zip component included in MELSOFT Update Manager. The following versions of Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M are affected: MELSOFT Update Manager SW1DND-UDM-M >=1.000A|

0
BreachCISA Alerts··1 min

Schneider Electric EcoStruxure IT Data Center Expert

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ IT Data Center Expert. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure. The following versions of Schneider Electric EcoStruxure IT Data Center Expert are affected: EcoStruxure IT Data Ce

0
BreachCISA Alerts··1 min

StoneFly Storage Concentrator

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to gain broad unauthorized access, execute arbitrary commands with root privileges, steal sensitive data, and perform actions on behalf of legitimate users across interconnected systems. The following versions of StoneFly Storage Concentrator are affected: Storage Concentrator <8.0.4.22 (CVE-2026-56415, CVE-2026-55721, CVE-2026-50040) Storage Concentrator Virtual Machine <8.0.4.22 (CVE-2026-56415, CVE-2026-5

0
BreachCISA Alerts··1 min

Frangoteam FUXA SCADA/HMI

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to enumerate all user accounts and role assignments on a FUXA SCADA/HMI instance. The following versions of Frangoteam FUXA SCADA/HMI are affected: FUXA SCADA/HMI <=1.3.1 (CVE-2026-13207) CVSS Vendor Equipment Vulnerabilities v3 7.5 Frangoteam Frangoteam FUXA SCADA/HMI Authentication Bypass by Spoofing Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and

0
BreachCISA Alerts··1 min

XZ Utils vulnerability impacting B&R Products

View CSAF Summary An update is available that resolves vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to stop or corrupt memory data. The following versions of XZ Utils vulnerability impacting B&R Products are affected: PPC3100 <1.8.1, 1.8.1 (CVE-2025-31115) C50 <1.8.0, 1.8.0 (CVE-2025-31115) C80 <1.8.0, 1.8.0 (CVE-2025-31115) FT50 <1.8.1, 1.8.1 (CVE-2025-31115) MT50 <1.8.1, 1.8.1 (CVE-20

0
BreachCISA Alerts··1 min

Delta Electronics DVP12SE PLC

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3 9.8 Delta Electronics Delta Electronics DVP12SE PLC Missing Authentication for Cri

0
BreachCISA Alerts··1 min

Russian Intelligence Services Continue to Target Commercial Messaging Applications

CISA and the Federal Bureau of Investigation (FBI) issued an updated Public Service Announcement (PSA) warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 Russian Intelligence Services Target Commercial Messaging Application Accounts and provides recent tactics, recommended mitigations, and samples of phishing messages.

0
BreachCISA Alerts··1 min

Daktronics Controller Firmware

View CSAF Summary Successful exploitation of these vulnerabilities could could provide an unauthenticated user with complete root-level access and control of the system. The following versions of Daktronics Controller Firmware are affected: VFC-DMP-5000 <v8.117.x.x VFC-DMP-5000 <v9.43.x.x VFC-DMP-5000 <v10.34.x.x DMP-5000 <v10.34.x.x DMP-5000 <v8.117.x.x DMP-5000 <v9.43.x.x DMP-8000 <v10.34.x.x DMP-8000 <v8.117.x.x DMP-8000 <v9.43.x.x CVSS Vendor Equipment Vulnerabilities v3 8.1 Daktronics Daktr

0
BreachCISA Alerts··1 min

Delta Electronics DTM Soft

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics DTM Soft are affected: DTMSoft vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics DTM Soft Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2

0
BreachCISA Alerts··1 min

OHIF Viewers DICOM

View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Public Health Count

0
BreachCISA Alerts··1 min

H.VIEW HV-500S6 IP Camera

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code and upload malicious files to the affected device. The following versions of H.VIEW HV-500S6 IP Camera are affected: H.VIEW HV-500S6 IP Camera IPCAM_V4.06.88.251229 CVSS Vendor Equipment Vulnerabilities v3 7.2 H.VIEW H.VIEW HV-500S6 IP Camera Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Unrestricted Upload of File with Dangerous Type

0
BreachCISA Alerts··1 min

pydicom pynetdicom Library

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0| =v1.0.0|<v3.0.4 Product Status: known_affected Remediations Vendor fix The maintainer of pynetdicom has not responded to requests to work with CISA to mitigate this vulnerability. For update information, refer to the github page https://github.com/pydicom/pynetdicom. https:

0
BreachCISA Alerts··1 min

Schneider Electric PowerLogic P7

View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control over system operations and disruption of critical services. The following versio

0
BreachCISA Alerts··1 min

Yokogawa FAST/TOOLS and CI Server

View CSAF Summary Successful exploitation of this vulnerability may return a response containing the CI Server setting information. The following versions of Yokogawa FAST/TOOLS and CI Server are affected: FAST/TOOLS >=R9.01| =R1.01| =R9.01| =R1.01|<=R1.04 Product Status: known_affected Remediations Vendor fix Yokogawa recommends users update FAST/TOOLS up to R10.04 and apply patch software (R10.04 SP4). Mitigation Yokogawa recommends users update Collaborative Information Server (CI Server) up

0
BreachCISA Alerts··1 min

Horner Automation Cscape

View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to disclose information and execute arbitrary code. The following versions of Horner Automation Cscape are affected: Cscape <10.2_SP3 CVSS Vendor Equipment Vulnerabilities v3 7.8 Horner Automation Horner Automation Cscape Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Ex

0
BreachCISA Alerts··1 min

EVoke Systems Charging Station Management System

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EVoke Systems Charging Station Management System are affected: EVoke CSMS vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 EVoke Systems EVoke Systems Charging Station Management System Missing Authentication for Critical Function, Imp

0
BreachCISA Alerts··1 min

OHIF Viewers DICOM

View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Public Health Count

0
BreachCISA Alerts··1 min

pydicom pynetdicom Library

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0| =v1.0.0|<v3.0.4 Product Status: known_affected Remediations Vendor fix The maintainer of pynetdicom has not responded to requests to work with CISA to mitigate this vulnerability. For update information, refer to the github page https://github.com/pydicom/pynetdicom. https:

0
BreachCISA Alerts··1 min

Using SASE in a Modern TIC 3.0 Solution

Using SASE in a Modern TIC 3.0 Solution CISA’s guidance, The Journey to Zero Trust – Using Secure Access Service Edge in a Modern TIC 3.0 Solution, details how the Trusted Internet Connections (TIC) 3.0 initiative is helping agencies modernize the way their users connect to applications, data and services. While federal agencies are the target audience, any organization looking to modernize its perimeter-based architectures, advance zero trust adoption, and improve visibility and control across

0